PP FAQs

Yes, in the event that the Physio 1611 pool requires relocating at a later date, the entire system can be dismantled and re-assembled.

The water storage tank and the equipment pack can be located within the room that the pool is located – a room of approximately 4.3 x 3.5 metres ( 14 x 11.6 ft) in size is required. If the tank and equipment pack are located remotely, then the pool will require a room of approximately 2.5 x 3.0 metres ( 8.3 x 10 ft). in size – Refer to drawings & specification sheet for confirmation.

The control panel allows system control settings, including the water temperature. The water temperature can be adjusted from ambient up to 40 Celsius (104 F) The Physio pool equipment has a in-built heavy duty stainless steel water heater. The water stored in the tank is constantly monitored and the heater is automatically activated when required, in order to maintain the set temperature. Generally for aquatic exercise, the water temperature will be set at 31- 33 Celsius ( 91.4F) - and for relaxation / vertical floatation treatments, the water temperature will be set at 36- 38 Celsius ( 96.8 – 100.4F) For chilled water set-ups, chilled water packages can be supplied.

Typically any solid ground level floor will support the weight of the Physio 1611 pool. If it is intended to locate the pool on a suspended floor (not ground floor) then additional support structure may be required eg: support columns etc..

As with all heavy items that are intended to be placed on flooring, it is required that a structural engineer be consulted to ensure suitability.

Electrical:

  1. 2 X standard 208 – 240 Volt, single phase, 50 / 60Hz, 25 Amp dedicated 
    GFCI protected supplies are required – ( available in most buildings 
    throughout Australia, North America, Europe, and Asia )
  2. A standard 120 or 240 Volt, 50 / 60 Hz, 10 Amp dedicated GFCI 
    protected supply is required

Plumbing:

  1. A Standard 40-50mm (1/12 - 2 inch) drain line is required - rigid or flexible 
    Connection.
  2. A standard 22mm (3/4 inch) Cold water supply is required.

Depending on the activity – for an energetic, express aerobic workout using the variable speed treadmill a 10 – 15 minute session will do the job. Extended work-outs with breaks can take 20 – 30 minutes. Sessions can be tailored to suit individual fitness level and objectives. Vertical flotation / relaxation treatments can last from 15 – 30 minutes - or extended sessions may be enjoyed. 

Page 1 of 4